MLU-1 documentation › Hardware specifications

Hardware specifications

Applies to MLU-1 (rev C and later) and MLU-1P · reviewed 2026-07-02

Two models, one software

Both models run the same software and are configured identically. The difference is power and storage, and it only matters in two situations: a comms cabinet with no free socket, and a site with secure release printing for more than about sixty people.

ModelPowerStorageUse it when
MLU-112 V DC external supply32 GB eMMC Default. Meter collection, alerts, release printing for a normal floor.
MLU-1PPoE (802.3af) or 12 V DC128 GB eMMC Cabinet installs with no mains socket, or heavy release printing where held jobs need room.

Specification table

ProcessorQuad-core ARM Cortex-A55, 1.6 GHz, fanless
Memory2 GB LPDDR4
Storage32 GB eMMC (MLU-1) / 128 GB eMMC (MLU-1P), industrial grade, wear levelling
Network2 × 1000BASE-T. eth0 = site LAN, eth1 = service port, fixed at 192.168.77.1/24
Other ports1 × USB-A 2.0 (backup and recovery media), 1 × micro-USB serial console (115200 8N1)
IndicatorsThree LEDs: power, status, activity. Patterns are listed in diagnostics.
Power draw5 W typical, 9 W peak during an upgrade
Dimensions108 × 82 × 26 mm, 240 g
MountingDIN rail clip (supplied), wall bracket (supplied), or flat on a shelf. Not rack ears — the unit is too small to span a rack and hangs badly from a shelf edge.
Operating temperature0 to 45 °C ambient, 10–90 % RH non-condensing
ClockReal-time clock with a soldered cell, holds time for about 30 days unpowered
SoftwarePrintDoc MLU firmware line 3.x. Current release documented here: 3.4.2

Ports and connectors

Looking at the unit with the LEDs towards you, left to right: power inlet, eth0, eth1, USB-A, micro-USB. The two Ethernet sockets are identical and unlabelled on rev C units, which is the single most common installation mistake — see cabling.

Mark the cables. Put a label on the site LAN cable at the unit end during the install. When somebody swaps the two later, discovery finds nothing, the console is unreachable from the LAN, and the first assumption is always that the unit has died.

Sizing: how many devices per unit

The limit is not the processor, it is how long a full polling pass takes. The numbers below are measured on a flat network with SNMP allowed end to end.

DevicesFull meter passRecommendation
up to 60under 1 minComfortable on either model.
60–1502–4 minStandard site. Leave the default 4-hour schedule.
150–2506–11 minSupported. Stagger scan ranges as described in discovery.
above 250—Second unit. Two units on one site do not talk to each other and do not need to; split by subnet, never by floor.

Secure release printing is sized separately, by held data rather than by device count. Budget 60 MB per active user per day and check retention before promising a long hold window on an MLU-1.

Where it may and may not live